Our field of activities in industrial electronics offers projects, planning, commissioning and maintenance of rectifiers for multiple applications.

 

We are your partner for:

 

> Digital exciter control equipment for rotative exciters of synchonous alternators and motors of 2 to 50 MW
> Static exciter equipment for alternators of 20 to 1200 MVA
> Revamping of rotative exciters into static exciters
> Starting invertors for gas turbine power stations or mixed duty equipment
> Rectifiers for the control of pump storage plants
> High current equipment for the supply of electrolysis and furnaces

 

Exciter equipment

Our static exciters have been in worldwide service for many years. The most frequent applications are alternators driven by gas, steam or water turbines of 20 to 1200 MVA. In order to increase the availability, the controls will be executed digitally and redundantly. The fans employed for cooling can be dimensioned, if desired, with the double capacity. We will design and elaborate solutions according to your wishes.

Our company is specialized in modernizing existing plants. We can substitute rotating exciters by static power electronics. Existing rotating exciters register remarkably high losses and have a time lag in controlling. The static execution of the exciter performs very dynamically in case of load disconnection and avoids high overvoltages. The inherent losses of a power station can be reduced notably and therefore the payback of the investment for the modification is secured.

Excitation equipment up to approx. 700A of the series TRM are supplied under the logo SEMIEXCITER for motors and alternators. For larger power plants, especially for alternators of power plants, we supply such equipment under the logo SEMIPOL..

Diagram of an exciter apparatus in modular execution as feeder for a rotating exciter

1. Main machine

2. Rotating diodes

3. Rotating exciter

4. Exciter energy

5. Excitation in short circuit

6. Actual value U gen

7. Actual value I gen

Design of a static exciter unit for small and medium machines

1. Main machine

2. Voltage transformer

3. Current transformer

4. Air gap reactor

5. Actual value U gen

6. Actual value I gen

Our supply includes the alternator measuring equipment and the alternator protection if desired.

A single line diagram of a SEMIEXCITER equipment for 100V and 600A is available as pdf file.

 

The following single line diagram shows three exciter equipments for alternators of 350 MVA each.

Digitale statische Erregeranlagen für ein Projekt mit 350 MVA Generatoren in einem Pumpspeicherkraftwerk 

 

Starting inverters

For refurbishing power stations we design and supply starting inverters for gas turbine sets with approx. 4 MW and large hydro turbine sets with a starting output up to 20 MW.

Start up system for generator and turbine shaft

Start up inverter for hydro generator

Anfahrsystem für die Generator- Turbinenwelle

Anfahrumrichter für Wasserkraftgeneratoren

For multiple alternator plants we supply commutation gear, so that one starting inverter can start e.g. 3 alternators.

 

Power electronic equipment for control of motor and alternator in pump storage plants

The following picture shows a 10 kV inverter for a synchronous alternator of 21,3 MW for reequipment of a pump storage plant. This 6-pulse inverter with intermediate circuit with constant current makes it possible to control the speed of a machine set with primary and secondary control of the line. Detailed information about the execution of the plant is available as pdf file.

 

High current plants and supplies for electrolysis and arc furnaces

We supply large DC converters for steel melting furnaces (EAF). For the chemical industry and different electrolysis plants we design water cooled rectifiers and transformers. The plants will be laid out according to the local requirements. We can supply rectifiers up to 1200 V and 40 kA in B6 connection or approx. 300 V and 60 kA with interphase transformers.. According to the requirements we can supply rectfiers with thyristors or diodes.

The central picture shows a rectifier with water cooling as a star connected rack (half a three phase bridge) for 15 kA in B6 connection.

 

Thyristor Converters

With the new series of thyristor converters Thyro-S, Thyro-A and Thyro-P of AEG we are presenting the new Thyro family which has a widespread communication property. High availability, reproducability and communicability are a basis for excellent and amply documented quality in application.

AEG thyristor converters operate, control and regulate electrical energy worldwide in industrial applications, beginning with simple tasks with low cost optimized analogous converters up to complex applications for highest requirements. AEG thyristor converters can be found where melting, heating, drying and transformation with precision and reliability are required. Apart from high product quality according to DIN EN ISO 9001, the Thyro family offers safety for application processes by experience in research and development. We can offer user specific solutions with special requirements.

Resistors

For heating equipment for the control of slipring motors, lifting magnets and other applications, our self cooling resistors are suitable. A resistor equipment consists of a casing and the built in resistors. The design varies between cast iron resistors, wire resistors , steel frames and grids. For a quotation, we need the duration of operation, type of application, the quantum of heating energy and the electrical data. For your inquiry you may use this pdf form.

 

 

 

AEG components / spare parts

AEG Industrial Engineering is supplier for industrial customers worldwide. For existing plants and applications we deliver spare parts, components and service. For AEG components and model series which are no longer available respectively discontinued we can naturally offer an alternative.

True to our motto “we take care of your power quality” we deliver:

Capacitors in various formats and building techniques, of course free of PCB and SF6. Our capacitors consist of low-loss coiled metallised polypropylene foils, which are processed to cylindric aluminium cases. The following types are available on short call:

 

Capacitors

Three-phase high power capacitors

Single phase capacitors

Gas dry capacitors

Gas capacitors

High-performance capacitors

 

TDGTDGplus

MKK

PAB DPM, PRB DPM

 

AEG Kondensator

Inductors in various formats and types, of course with low power dissipation and high durability.

Inductors

Filter circuit inductors

Discharge inductors

 

FR@ 

DD6NM - DD16NM

 

AEG Drossel

AEG Drossel

 

Controller and analytical devices

 

Reactive Power Controller

Power Analyzer

Capacitor protective relays

Voltage control relays

 

RP-con 1100

BLR-CX, BLR-CM

BLR-CA, BLR-CB,

BLR-CC, BLR-MC,

BLR-K, BLR-BK,

EMM3, EMM4, EMM5

KSR, VCR, VSR

 

 

Control  components for various applications

 

Contactors

Alternating current contactors

Rotary current contactors

Capacitor contactors

Direct voltage contactors

DC-bus contactors


 

LS-K

K

LS

LS-KCW

 

AEG Schütz

 

Rail contactors HzS-Contactors

Bahnschütz

 

Switch relays

RH(M)1000

RH(M)1003

RH(M)1004

 

Schaltrelais

 

Electromechanic hydraulic actuators Eldro actuators

Eldro-Stellgerät

 

Transducers

Measuring transformers

Support current transformers

Transformers

Potential transformers

Ring core transformers

Coil transducers

Busbar transformers

 

IL, IS, CT,

EK, ES, ZK, ZS,

EY, ZY, ZYE, EYS,

K, RK, PRK,

SRY, DY, RY

 

Wandler Wandler

Messwandler

Thyristor controllers

Control devices for process engineering

 

Thyro-A, Thyro-P,

Thyro-S, Thyro-C,

Thyro-M

 

AEG Thyro AEG Thyro

AEG Thyro

 

Rectifier modules / slide-in

Converter mudules / slide-in

Battery charging devices

Compact UPS

 

AC1000, AC2000,

AC2800, AC 7000

DC 500, DC1000, DC2000, 

DC 3000

 

 

Compensation equipment

Dynamic compensation

Passive filters, filter circuits

Active filters

 

AE TDG

MKK

AcF

 

 

Drive technology

 

Three phase ac motors

Asynchronous motors

Squirrel-cage motors

Short circuit rotors

Direct current motors

Slip ring rotors

Static unbalance motors

Vibration motors

 

A, AM, AMBX, EAM,

AJ, AN, AR, AU, AW, A5E, A5L,

CA, DA, KA, KA,

G, GC, GK, GS,

G5L, G5K,

UVB, UVC, UVD, UVE, UVF, UVG, UVH, UVL, UVN, UVP

 

 

Generators

Generator controls

 

DKBH, DKBL

TR5D

 

AEG Generator

 

Power converter

Frequency inverter

Microsemi, Minisemi, Maxisemi, Powersemi, Modulverter, Microverter, Miniverter, Maxiverter, Monoverter, Multiverter

 

Autotransformers

Softstarter

 

 

 

Liquid starters

 

Low voltage / medium voltage switching equipment

 

NH protection bars

Low voltage switches

Disconnectors

Isolator switches

Load isolator switches

Protection load isolator switches

Motor protection switches

 

HSE, HSEV,

DILOS, FULOS,

LTSiSt

Mbs

 

 

Circuit breakers

Isolator switches

DC voltage circuit breakers

DC voltage isolator swiches

Direct current switches

DC fast breakers

 

ME00, ME07,

MEG, MEGT,

MEY-Rapid,

Gearapid, GEARAPID

Gerapid, GERAPID

 

 

Medium voltage circuit breakers

Vacuum circuit breakers

Furnace breakers

Disconnectors

Disconnecting switches

Load isolator switches

Protection load isolator switches

 

VA, VAA, VXA, VXB VXC, VAH,...

AL, BAL

 

 

 

Electronic components

 

Protection devices

Grid protection

Line protection

Transformer protection

Generator protection

Differential protecting systems

 

PQ721, PQ731, PQ741,

PQ751,

PS421, PS431, PS451

 

 

Electronics

Electronic cards

Electronic circuits

 

MCU, CCU,

DAP, DEP,

Logidyn DK

 

 

Widerstandsgeräte

Ohmic resistors

Rotor resistance

 

 

Thyristors

Diodes

Insulated-gate bipolar transistors (IGBT)

Thyristor modules

Diode modules

Powerblock

Presspack

 

T, D, TT, DD, DT, TD

 

 

We take care of your power quality